October - 2010
Previous Next | Showing Journal 7 of 17 |
Intermittent Subglottic Secretion Drainage and Ventilator-associated Pneumonia: A Multicenter TrialJean-Claude Lacherade, Bernard De Jonghe, Pierre Guezennec, Karim Debbat, Jan Hayon, Antoine Monsel, Pascal Fangio, Corinne Appere de Vecchi, Cédric Ramaut, Hervé Outin, and Sylvie Bastuji-Garin American Journal of Respiratory and Critical Care Medicine, 2010, 182: 910 - 917. This page is only available to Crit-IQ subscribers. To view the rest of this review and gain access to our vast array of critical care teaching tools including podcasts, vodcasts, modules, exam preparation tools, teaching aids and much more, login here, or Become a Member to register |
October |
Previous Comments
No Comments yet.
Comment
Its looking like its going to be very hard to ignore the supraglottic suction tubes. This paper ads to the evidence base, reducing the incidence of VAP from 25% to 14%.